9.3
Zone Heaters
A zone is an area in the poultry house. Each zone heater can be mapped to specific
temperature sensor(s) and operates according to that sensor’s data output. The heat set
point in the temperature curve is the same for all zones. Once a zone’s heater is activated,
it will work to maintain the temperature. All zone heaters work independently.
Define relays output ports as heaters. Refer to the Installation Manual.
In Configuring the Temperature Curve, page 22 define the Heat parameter.
To define the zoned on/off heaters:
1. Go to System > Control Strategy > Climate .
2. Define the Heating Method as Zoned.
3. Go to Climate > Heating.
4. Define:
o
Heater On Temp: Define the difference from the Heat target temperature at
which the heaters turn on. Range: 0.2 - 5⁰ C.
o
Heat Tuning: This parameter determines how aggressively the TRIO
responds to differences between the measured temperature and the target
temperature.
NOTE Munters recommends leaving this parameter at Normal.
5. Go to System > Temperature Definition.

Table of Contents

Other manuals for Munters Trio Poultry Controller

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Munters Trio Poultry Controller and is the answer not in the manual?

Munters Trio Poultry Controller Specifications

General IconGeneral
BrandMunters
ModelTrio Poultry Controller
CategoryController
LanguageEnglish

Related product manuals