CHAPTER 3 SYSTEM DATA PROGRAMMING
– 107 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Assign the data for wireless synchronization
between IP-CSs, if required.
NOTE: Data setting of CMAD Y=32-39 is
not required for a normal operation.
You do not have to change the data
from initial setting.
(1)
(2)
Y=32 (Timing until Submaster IP-CS starts
up)
000-255: CS No.
01-14: 6-84 seconds
(6 second increments)
15 : 30 seconds
(1)
(2)
Y=33 (Time limit for initial synchronous
processing)
000-255: CS No.
01-14: 1.5-21 seconds
(1.5 second increments)
15 : 15 seconds
(1)
(2)
Y=34 (Time limit for receiving the notice
message of wireless channel infor-
mation at the synchronous process-
ing)
000-255: CS No.
01-14: 100-1400 ms.
(100 ms. increments)
15 : 500 ms.
(1)
(2)
Y=35 (Number of continuation synchro-
nous bit off message for judging a
gap)
000-255: CS No.
01-14: 1-14 messages
15 : 4 messages
(1)
(2)
Y=36 (Time limit for receiving the LCCH
for judging a gap)
000-255: CS No.
01-14: 1.5-21 seconds
(1.5 second increments)
15 : 6 seconds
D