CHAPTER 3 SYSTEM DATA PROGRAMMING
– 127 –
NWA-008855-001 Rev.1.0
avch3001.fm
DESCRIPTION DATA
Specify the DTMF Sender release timing to the
trunk route.
(1)
(2)
Y=46
00-63: Trunk Route No.
0 : 2 seconds
1 : 4 seconds
2 : 6 seconds
3 : 8 seconds
4 : 12 seconds
5 : 14 seconds
6 : 16 seconds
7 : 10 seconds
Assign the speech volume control data.
(1)
(2)
Y=47
00-63: Trunk Route No.
0 : Receiver + 5 dBr (5 dB up)
Transmitter + 3 dBr (3 dB up)
1 : Receiver + 5 dBr (5 dB up)
3 : No amplification
Specify the designated seizure of trunks on
each station basis.
(1)
(2)
Y=98
00-63: Trunk Route No.
0: Allow
Assign the trunk to be seized on each Virtual
station basis.
(1)
(2)
Y=16
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
D000-D255: Trunk No.
Assign Service Restriction Class A to the re-
quired Virtual station.
(1)
(2)
Y=02
X-XXXXXXXX: Virtual Station No. as-
signed by CM14
XX ZZ
XX: 00-15 : Service Restriction Class A
Allow the sending Switch Hook Flash for Ad-
junct Analog System in Service Restriction
Class A assigned by CM12 Y=02.
(1)
(2)
Y=146
00-15: Service Restriction Class A
assigned by CM12 Y=02
0: Allow
D
CM35
CM12
CM15
E
TRUNK DATA PROGRAMMING (For Adjunct Analog)