PS Location Indication
ND-91638-007(E) Page 31
Issue 6
14-2-1) When PS 200(CS Name: Conf. Room #200) makes a call to PS 201(CS Name: Conf. Room #201) that
sets Call Forwarding-No Answer to D
term
-A, the display on the D
term
-A is as follows:
Called PS No. Calling PS No.
CS Name of calling PS
Note: CS Name of the intermediate PS is not displayed.
14-2-2) When PS 200(CS Name: Conf. Room #200) makes a call to PS 201(CS Name: Not Display, PS Name:
Yamada) that sets Call Forwarding-No Answer to D
term
-A, the display on the D
term
-A is as follows:
Intermediate PS No. Calling PS No.
Intermediate PS Name CS Name of Calling PS
Note: Intermediate PS Name is displayed.
14-2-3) When PS 200(CS Name: Conf. Room #200) makes a call to PS 201(CS Name: Not Display, PS Name:
Not Assigned) that sets Call Forwarding-No Answer to D
term
-A, the display on the D
term
-A is as fol-
lows.
Intermediate PS No. Calling PS No.
CS Name of Calling PS
14-3) When PS 200(CS Name: Conf. Room #200) makes a call to D
term
-A(Extension: #301, PS Name: Ya-
mada) that sets Call Forwarding-No Answer to D
term
-B, the Display on the D
term
-B is as follows.
D
term
-A No. Calling PS No.
D
term
-A Name CS Name of Calling PS
Note: The name of the intermediate D
term
is displayed.
Note 1: When the called D
term
is a D
term
65 Series, there are following conditions.
Max. 16 characters of name of the calling PS (#200) is displayed.
When name of the calling PS (#200) is 9 through 16 characters, name of intermediate D
term
(#301)
is displayed.
When the name of the calling PS (#200) is 1 through 8 digit(s) or is not assigned, max 8 characters
of name of the intermediate D
term
(#301) is displayed. (When the name of the called D
term
(#301)
is more than 8 characters, only 8 characters are displayed.)
Note 2: When the called D
term
is a D
term
75 Series, there are following conditions.
Max. 16 characters of name of the calling PS (#200) is displayed.
Max. 8 characters of name of the intermediate D
term
(#301) is displayed. (When the name is more
than 8 characters, only 8 characters are displayed.)
200
Conf. Room #200
201Forward
200
Conf. Room #200
201Forward
Yamada
200
Conf. Room #200
201Forward
200
Conf. Room #200
301Forward
Yamada