NMC-PRO
USER GUIDE
Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 45
Crop Management Technologies
IMPORTANT: Verify that the SETUP parameters have been
defined for heating!
# Parameter Explanation Unit/Range Default
1.
Period
It is possible to divide the day up to 6
periods. You can decide if the period is
On/Off.
On/Off On
2.
Active
Updated by the controller
(For indication only)
Yes/No
3.
Start Time
Start Time of the period. In case of
overlapping periods, the next period
overrides the previous period.
hh:mm --:--
4.
Heating
Temperature
The desired heating temperature in the
specific climate zone.
0
o
to +50
o
C 20
5.
Radiation
Influence
A four point table that defines the
conversion of the influence of the outside
radiation on the set heating temperature
within that zone.
0 - 2500
W/m2
to +100°
C
6.
Cool Down Time
Define the gradual cooling down time per
1
o
C (approximately 2F). This is used to
avoid fast changes between periods.
hh:mm 00:00
7.
Heat Up Time
Define the gradual heating time per 1
o
C
(approximately 2F). This is used to avoid
fast changes between periods.
hh:mm 00:00
8.
Use ON/OFF
Heating
Option to enable or disable the ON/OFF
heater.
Yes/No Yes
1.3 Heating Prg. Zone 1 19/01/09 10:21
1. Period
2. Active
3. Start hh:mm
4. Heating temp °C
5. Rad influence
6. Cool time hh:mm
7. Heat time hh:mm
1
On
Yes
06:00
17.0
00:15
00:15
2
On
No
15:00
22
00:15
00:15
3
Off
Calculated/Status
15. GH calculated temp °C
16. Calc. ON/OFF heat. temp °C
17. Limitation
19.0
23.5
None