IMPORTANT: Verify that the SETUP parameters have been
defined for Misting!
# Parameter Explanation Unit/Range Default
1.
Period
It is possible to divide the day up to 6 periods.
You can decide if the period is On/Off.
No/Yes No
2.
Active
Updated by the controller
(For indication only)
Yes/No
3.
Start Time
Start Time of the period. In case of
overlapping periods, the next period overrides
the previous period.
hh:mm --:--
4.
Release Misting
Yesmisting valve opens for misting event.
Nomisting valve does not open and the
misting process will not start.
Yes/No Yes
5.
Start Misting
trigger
Select a START trigger from the list. After the
period starts, the system will check the trigger
and determine if to open the misting valves
and start the misting process.
None – the misting process does not start
Temp
Humidity
VPD
None
None
6.
Stop Misting
trigger
Select trigger from the list. After misting
program is in process, the system will check
the stop trigger, and determine if to stop the
misting process completely until a Start
trigger is recognized.
NONE - misting stops according to dead band
limit of the start trigger
Temp
Humidity
VPD
None
None
1.4 Misting Prg. Zone 1 19/01/09 7:21
1. Period
2. Active
3. Start hh:mm
4. Release
5. Start trig.
6. Stop trig.
7. Temp limit °C
1
Yes
Yes
06:00
Yes
Temp
Temp
0.0
2
Yes
No
08:00
Yes
VPD
VPD
---
3
No
No
Calculated/Status
13. Start trigger
14. Misting status
15. Limitation
Temp
On
NONE