NMC-PRO
USER GUIDE
Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 58
Crop Management Technologies
# Parameter Explanation Unit/Range Default
7.
Temp limit
If ‘Temp’ is selected as the Start/Stop trigger,
then above this set point, the misting program
will start and below the dead band, the
misting will stop.
°C 0.0
8.
Temp dead band °C 0.0
9.
Hum limit
If ‘Hum’ is selected as the Start trigger, than
below this set point, the misting program will
start and above the dead band, the misting
will stop.
If ‘Hum’ is selected as the Stop trigger, than
above this set point, the misting program will
start and below the dead band, the misting
will stop.
0 - 100% 0
10.
Hum dead band 0 - 100% 0
11.
VPD limit
If ‘VPD’ is selected as the Start trigger, than
above this set point, the misting program will
start and below the dead band, the misting
will stop.
If ‘VPD’ is selected as the Stop trigger, than
below this set point, the misting program
starts and above the dead band, the misting
stops.
kPa 0.0
12.
VPD dead band kPa 0.0
Calculated / Status
13.
Start trigger
Displays the trigger that will activate the
misting system.
1. VPD
2. Humidity
3. Temperature
4. None
14.
Misting system
status
Current status of the misting system.
On/Off
15.
Limitation
Misting system may be limited due to a higher
priority event.
Ex: If the Crop Protection system is activated,
then the misting system will be inactive
and the Limitations will display Crop Pro.
1. Manual
2. External input
3. Crop Protection
4. None