Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 73
Crop Management Technologies
Measurements
7.
Calculated position – Targeted position of the inlet
8.
Measured position – Current position of the inlet
9.
Control type – Method of which the inlet movement is measured (time/measured)
10.
Measured mV – Current mV read by the potentiometer corresponding with the inlet
position
11.
Curve mV – Defined position of the inlet according to the mV read by potentiometer
during calibration
NOTE: DO NOT EDIT MANUALLY
12.
Limitations – Restrictions on calibration process due to higher priority processes