NMC-PRO
USER GUIDE
Doc. Name: NMC-PRO ׀ User Guide Ver 3.05.03 Revision: 2.2 Page: 90
Crop Management Technologies
# Parameter Explanation Unit/Range Default
8.
Misting
Define activity of MISTING during Crop
Protection:
Freeaccording to Misting program
Nodisables Misting during Crop
Protection
Free/No No
9.
Air Circulation
Define activity of AIR CIRCULATION during
Crop Protection:
Freeaccording to Air Circulation
program
Yes – turns Air Circulation ON during Crop
Protection
No – disables Air Circulation during Crop
Protection
Free/Yes/No No
10.
Maximum vent
LEE
For Purge phase only, the user can define
the position of the vents.
The Crop Protection program takes control
of the vent minimum and maximum
positions.
0 - 100%
100%
11.
Minimum vent
LEE
0
12.
Maximum vent
WIND
100%
13.
Minimum vent
WIND
0