EasyManua.ls Logo

NetApp E5700 - Install New Power Canister; Complete Power Canister Replacement

NetApp E5700
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Press the orange latch on the power canister cam handle, and then open the cam handle to fully
release the power canister from the mid plane.
6. Use the cam handle to slide the power canister out of the shelf.
Attention: When removing a power canister, always use two hands to support its weight.
After you finish
Go to
Install new power canister
on page 45.
Install new power canister
You install a new power canister to replace the failed one. When you install a power canister, you
slide the component into the shelf, close the cam handle, reconnect the power cord, and reapply
power.
Before you begin
You have a replacement power canister that is supported for your controller shelf or drive shelf
model.
You have checked that the on/off switch of the new power canister is in the Off position.
Steps
1. Using both hands, support and align the edges of the power canister with the opening in the
system chassis, and then gently push the power canister into the chassis using the cam handle
until it locks into place.
Attention: Do not use excessive force when sliding the power canister into the system; you can
damage the connector.
2. Close the cam handle so that the latch clicks into the locked position and the power canister is
fully seated.
3. Reconnect the power cord to the power canister, and secure the power cord to the power canister
using the power cord retainer.
4. Turn on the power to the new power canister.
After you finish
Go to
Complete power canister replacement
on page 45.
Complete power canister replacement
You complete the power canister replacement by confirming that the new power canister is working
correctly. Then, you can gather support data and resume normal operations.
Steps
1. On the new power canister, check that the green Power LED is on and the amber Attention LED
is OFF.
2. From the Recovery Guru in SANtricity System Manager, select Recheck to ensure the problem
has been resolved.
3. If a failed power canister is still being reported, repeat the steps in
Remove failed power canister
on page 44 and
Install new power canister
on page 45. If the problem continues to persist, contact
technical support.
Canisters |