2.25 EDH0162En1040 – 06/99
MM4005 Local Mode
2.2.2.18 Maximum Position
This parameter defines the positive (usually right) software travel limit. No
motion will be allowed to exceed this position in the positive direction.
CAUTION
Do not set a higher value for this than the default value, otherwise the
hardware limit switch will be tripped.
To change the positive software travel limit, press the key. Use the
numeric keypad to enter a new value and then press to accept the
setting and return to the previous menu.
Press the key to advance to the next parameter.
→→→→→→
→→→
SR — Set right travel limit.
TR — Read right travel limit.
2.2.2.19 HOME Preset
This feature is used to set the zero location according to the application’s
needs.This parameter defines the value that will be loaded into the position
register when the motion device’s home is found. The factory default is
zero, meaning that at the home location the position is zero. If, for instance,
this parameter is set to 12.3 mm, at the home location the controller
reports position 12.3 mm.
Do not set a value for the HOME Preset parameter that is outside the soft-
ware travel limits.
To change the HOME Preset parameter, press the key. Use the
numeric keypad to enter a new value and then press to accept the
setting and return to the previous menu.
Press the key to advance to the next parameter.
→→→→→→
→→→
SH — Set home preset position.
XH — Read home preset position.
QUITYESQUITQUIT
VALID