Beacon G6 unit data sheet
Beacon G6 detailed specifications
Table 5-7 Beacon G6 indoor physical specifications (continued)
Table 5-8, “Beacon G6 indoor power consumption specifications” (p. 47) lists the power
consumption specifications for Beacon G6.
Table 5-8 Beacon G6 indoor power consumption specifications
Maximum power
(Not to exceed)
2 1000/100/10 Base-T Ethernet, 2
x 2.5G/1000 M /100/10 BASE-T
Ethernet,WI-Fi operational
Wi-Fi active, other interface /
service not provisioned
Table 5-9, “Beacon G6 environmental specifications” (p. 47) lists the environmental specifications
for Beacon G6 indoor .
Table 5-9 Beacon G6 environmental specifications
Temperature range and humidity
Operating: -5°C to 45°C (23°F to 113°F) ambient
temperature
95% relative humidity, non-condensing at 40°C
Contact your Nokia technical support representative for
more information
Storage: -25°C to 70°C (4°F to 185°F)
Table 5-10, “Beacon G6 dimension data specifications” (p. 47) lists the dimension data
specifications for Beacon G6
Table 5-10 Beacon G6 dimension data specifications
Less than 2000 jumbo frames
Max MTU of IP diagram -1500
Number of IP addresses supported (or ranges)
In LAN network, the supported range is:
• IPv4: 192.168.1.2 - 192.168.1.254 (default)
• IPv6: no limitation
Number of supported Wi-Fi clients (per radio, per device, per
mesh)
• 128 clients per radio
• 128 clients per device
• 256 clients per mesh supported
Number of supported beacons /APs in a mesh