Setup
3-6
Part 1108061-02
E 2015 Nordson Corporation
2. Floor Blowoff Delay Between Pulses (sec.): Enter the time, in
seconds, to wait between each pulse of air (between steps).
3. Floow Blowoff Pulse Duration (sec.): Enter the time, in seconds, for
the duration of each pulse (step).
4. Gun Blowoff ON Duration (sec.): Enter the time the gun blow-off
solenoid must be open in order to clean the exterior of the automatic
guns. This is usually the time it takes to retract the guns from full in to
full out.
Touch the Next Setup button on the Blowoff Setup screen to open the Floor
Blowoff Setup screen. Assign the floor blow-off solenoids to steps by
touching the step field and entering a step number for each solenoid. This
screen shows the steps configured for the 9 meter booth example on the
preceding page.
Figure 3-9 Floor Blowoff Setup Screens Nordson Screens and Functions