7-5
7.3. Readout Command
l If a command for reading out initial setting or current state is entered, the Driver Unit returns data.
l The following is an example for checking “Jog Velocity JV” set value.
7.3.1. “TS” Command for Reading Set Value
1) When entering the command, make sure that a colon ( : ) is displayed on the screen.
(If the colon is not displayed, press the enter key once.)
:_
ENT
2) Refer to “12. Command and Parameter.”
“JV” command is in the group of TS7, input
:TS7
MV1.00;
ENT
S 7
T
The setting value of MV (Move Velocity) is displayed first.
3) Press the space key to scroll display to find out JV value.
:TS7
MV1.00;
MA1.00;
JV0.10;
SP
···
SP
4) To finish the readout, keep pressing the space key until display stops scrolling or press the back
space key.
MV1.00;
MA1.00;
JV0.10;
:_
BS
5) The colon ( : ) is displayed to indicate the system is waiting for next command.