9-8
9.1.8. In-Position Output
l In-Position output condition is determined by the following parameters.
Table 9-1
Parameter Function (Name) Shipping set
FW IPOS outputting time range (Output mode) FW1
IN In-Position limit value IN100
IS In-Position stability timer IS0
Figure 9-9
FW value
Example FW1: 100 ms
Close
Open
IPOS output
IPOS mode (FW = 0)
Close
Open
Determined by the IS set value
Example IS1: 0.1 sec
Position error counter
residual pulse
IPOS output
IPOS mode (FW = 0)
IPOS output
FIN mode (FW
0)
Pulse command
Position error
RS-232C communication
command or RUN input
Close
Open
IR100
IN value
IN set value