EasyManua.ls Logo

NSK MEGATORQUE M-ESA-Y2005V25 - Appendix 2: How to Check Motor Condition

Default Icon
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-5
Appendix 2 : How to Check Motor Condition
l Examine resistance and isolation of Motor windings to find out its condition.
l Firstly conduct the checks with the Cable Set. If the result does not meet the specification, check
the Motor only.
1 Resistance of Motor windings
Figure A-5: With Cable Set
(Tester)
Connector Lock
Resolver Cable
Motor Cable
1
2
3
4
5
6
7
l Refer to Table A-3 for pin numbers to be checked.
Figure A-6: Motor only
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
(Tester)
(Connector Lock)
l Refer to Table A-3 for pin numbers to be checked.
Table A-3 : Pin number to be checked.
Cable connector Motor connector Result
Phase A
1
2
(A+) (A-)
5
4
(A+) (A-)
Phase B
3
4
(B+) (B-)
10
9
(B+) (B-)
Phase C
5
6
(C+) (C-)
15
14
(C+) (C-)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com