EasyManua.ls Logo

NSK MEGATORQUE M-ESA-Y2005V25 - Home Return Parameter List; Adjusting Home Position Switch and Home Offset Value

Default Icon
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-5
10.2.1.1. Home Return Parameter List
Table 10-2 : Motor series : YS, JS1, JS2 and RS
Parameter function
RS-232C
Parameter
Unit Data input range Shipping set
Home Return Acceleration HA s
-2
0.01~80.00 1.00
Home Return Velocity HV s
-1
0.0001~3.0000 0.2
Home Position Offset HO pulse 0~610 304 0
Home Return Direction HD 0: CW, 1: CCW 1
Home Return Near-Zero Velocity HZ s
-1
0.0001~0.20 0.0100
Table 10-3 : Motor series : SS
Parameter function
RS-232C
Parameter
Unit Data input range Shipping set
Home Return Acceleration HA s
-2
0.01~100.00 1.00
Home Return Velocity HV s
-1
0.0001~3.7500 0.2
Home Position Offset HO pulse 0~487 424 0
Home Return Direction HD 0: CW, 1: CCW 1
Home Return Near-Zero Velocity HZ s
-1
0.0001~0.25 0.0100
Table 10-4 : Motor series : AS, BS and JS0
Parameter function
RS-232C
Parameter
Unit Data input range Shipping set
Home Return Acceleration HA s
-2
0.01~120.00 1.00
Home Return Velocity HV s
-1
0.0001~4.5000 0.2
Home Position Offset HO pulse 0~405 504 0
Home Return Direction HD 0: CW, 1: CCW 1
Home Return Near-Zero Velocity HZ s
-1
0.0001~0.30 0.0100
10.2.1.2. Adjusting Home Position Switch and Home Offset Value
l The position of the Home position sensor (a dog or a sensor) must be adjusted properly to perform
Home Return accurately.
l The Home position is determined at the point where the resolver value becomes zero after detection
of HLS input rising edge when motor is running under Home Return near-zero velocity. (The home
position is set to the point that is off-set by HO, if the Parameter HO value is not set to 0 (zero).)
l The resolver has many teeth for detecting its position and the rising edge of HLS is to identify a
tooth out of these teeth. To make precise detection of øZ, the Home limit switch position must be
adjusted so that the HLS input goes high when the switch is at the middle center of the tooth width.
Design the Home limit switch so that it can be adjusted ±1.2° or more in relation to the tooth width.
l Take the following steps to adjust the position of the Home limit switch.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com