— 4-24 —
4.2.2. General Specifications
u Control mode
l Closed loop, P·I position control
u Operation mode
l Pulse train position command
l RS-232C serial communication command
l Programmable control
l Return Home operation
l Jog
u Power supply capacity
1 AC200V/220V ±10%
Table 4-5 : Power supply capacity
Driver Unit Reference No.
Main power Max.
(exclude surge current)
Control power Max.
(exclude surge current)
M-ESA-Y2005T25 0.5 kVA
M-ESA-Y2020T25 1.0 kVA
M-ESA-Y3008T25 0.6 kVA
M-ESA-Y3040T25 1.2 kVA
M-ESA-Y4080T25 1.4 kVA
M-ESA-Y5120T25 1.5 kVA
M-ESA-Y5240T25 2 kVA
M-ESA-J0002T25 0.7 kVA
M-ESA-J1003T25 0.7 kVA
M-ESA-J2006T25 0.9 kVA
M-ESA-J2014T25 1.0 kVA
50 VA
* For the power supply capacity of RS and SS series motors, refer to their specification
document.
Table 4-6 : Surge and leakage current
Control power Main power
Surge current 14A 140A
(40
Hz
~ 1
kHz
) 5 mA rms
Leakage current
( ~ 1
MHz
) 35 mA rms
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com