Loading...
9-35
9.3.2.4. Canceling Command
l A command which has been entered halfway, entering a backspace code (08H) can cancel a
character or an entered full character string. Parameter “backspace mode” (BM) sets the
cancelling method.
BM0 : a backspace code cancels an entered character string.
BM1 : a backspace code cancels a character.
[When the Handy Terminal FHT11 is used, press the backspace (BS) key.]
1 Parameter “BM1” (Shipping set)
l For example, when the backspace code is input following VG0.5, the cursor moves one space back
to the position where 5 was input and thereby deletes 5.
Figure 9-37: Canceling example (BM1)
:VG0._:VG0.5_
Input BS Key
(08H)
Input (To Driver Unit)
08H5.0GV
Echo back (From Driver Unit)
20
H
08
H
08
H
5.0GV
2 Parameter “BM0”
l For example, when the backspace code is input following VG0.5, a message “VG0.5?” and a colon
“ : ” are displayed and thereby deletes “VG0.5.”
Figure 9-38: Cancelling example (BM0)
:VG0.5
VG0.5?
:_
:VG0.5_
Input BS Key
(08H)
Input (To Driver Unit)
08H5.0GV
Echo back (From Driver Unit)
0AH0DH (b)(a)
(b)
:
0A
H
0D
H
5.0GV
?5.0GV
(a)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com