EasyManua.ls Logo

NSK MEGATORQUE M-ESA-Y2005V25 - History of Alarm; Indication of History of Alarm; Clear History of Alarm

Default Icon
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14-15
14.2.5. History of Alarm
l Store the occurrence of alarms to EEPROM.
l It keeps the record of alarms up to 32nd before.
l It does not overwrite more than 32nd alarm. Clear the alarm history to keep the record for new
alarms.
l This history records the alarm which makes the DRDY output open.
l Contents of record are as follow.
(i) Alarm code that is shown on LED.
(ii) Details of alarm for failure analysis of the manufacturer.
(iii) The number of times the power is turned on.
Caution : History of alarm may not be stored properly when the power is shut off right
after the alarm is reported.
14.2.5.1. Indication of History of Alarm
(1) Input TA command. Press SP key to scroll next line.
:TA/HI
now time=8
0>F1-0, 1;
1>F1-0, 4;
2>F1-0, 4;
3>F1-0, 4;
4>A1-0, 4;
:_
HA /
···SP
T
ENT
I
The current number of
times for turning on power.
The number of times for
turning on power when the
alarm is reported.
Details of alarm.
Old
Alarm code.
Number of alarm.
14.2.5.2. Clear History of Alarm
(1) Input password.
:/NSK ON
NSK ON
:_
KN S/
SP
N
ENT
O
(2) Input TA command.
:/NSK ON
NSK ON
:TA/CL
:_
CA /T
ENT
L