6-12
6.4.3. Motor Thermal Protection
l The thermal protection circuit must be installed to prevent the Motor from overheating.
l YS and JS Motors have a built-in thermal sensor. The lead wires of the sensor are connected to the
Motor connector.
l A Cable Set has the outlet lead wires for the protection circuit. Refer to “3.2.3. Cable Set” for
sensor lead wires.
l The protection circuit must be set to turn off the main AC power supply when the sensor is
activated. Refer to Figure 6-8 “Wiring Example” to install the protection circuit that uses 2 lead
wires S1 and S2.
l Thermal sensor specifications
Contact : Normally close
Rating Maximum : 250VAC 3.5A
Rating Minimum : 6V 0.15A
Type : T100R1U1N ( Matsushita Electric )
(Temperature set : 100°C)
Conforms to VDE.
The sensor is “self resetting” type. When temperature drops 15°C from the set value, it
returns to normal state. Wait for 30 minutes or more after the protection circuit is
activated and then turn on the power again.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NSK MEGATORQUE M-ESA-Y2005V25 and is the answer not in the manual?

NSK MEGATORQUE M-ESA-Y2005V25 Specifications

General IconGeneral
BrandNSK
ModelMEGATORQUE M-ESA-Y2005V25
CategoryServo Drives
LanguageEnglish

Related product manuals