11-2
11.1. Commands and Parameters
u Home Return
Command : HS
Condition setting : None
l Program Home Return operation.
l Command format : HS seq
seq : sequence code (*, &) Refer to “Sequence Code” in the next page.
l The Motor rotates according to the values set by Home Return velocity HV, Home Return
acceleration HA, Home Return near-zero velocity HZ, and to the direction set by Home Return
direction HD.
Caution : Direction of Home Return may be reversed using HD parameter.
HD0 : CW direction
HD1 : CCW detection (Shipping set)
*Program example
:CH0
HS
u Positioning
Command : AD, AR, ID, IR
Condition setting : CV, CA (Can be omitted.)
l Program the Indexing motion profile.
Table 11-1
Command format Outline Option
AD d1 d3 seq
Absolute indexing, in the unit of degree.
The Motor turns to reach the d1 [× 0.01°]
position of position scale.
AR d1 d3 seq
Absolute indexing in the unit of pulse.
The Motor turns to reach the d1 [pulse]
position of position scale.
Option code d3
/PL: CW direction
/MI: CCW direction
When d3 is omitted, the Motor turns in the shortest-
distance direction to reach the d1 position.
ID d1 d2 seq
Incremental indexing, in the unit of degree.
The Motor makes a d1 [× 0.01°] turn from
the present position.
IR d1 d2 seq
Incremental indexing in the unit of pulse
The Motor makes a d1 [pulse] turn from the
present position.
Option code d2
/n: (n <= 99)
When d2 is specified, the d1 value is equally divided by
n. Single RUN input will make motor rotate by the
divided amount.
When d2 is omitted, the d1 value will not be divided.