EasyManua.ls Logo

NSK MEGATORQUE M-ESA-Y2005V25 - MN: Monitor; MO: Motor off; MS: Motor Stop

Default Icon
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-23
MN : Monitor
Format : MN data
Data : 0 ~ 7
Shipping set : 0
Default : 0
l Selects and sets the condition of the analog monitor.
l The setting is not backed-up in the memory. “MN” command must be entered when monitoring is
required.
l Setting can be read by “?MN” command.
l The condition of monitor is shown in the table below.
MN data Monitor output
MN0 Velocity
MN1 Velocity command
MN2 Velocity error
MN3 Torque command
MN4 Phase C current command
MN5 Position command
MN6 Position error (± 127 pulses / ± 10V)
MN7 Position error (± 16 383 pulses / ± 10V)
MO : Motor Off
Format : MO
l When the SVON input (CN2) is ON and the Motor is in the servo-on state, inputting the “MO”
command turns the Motor servo off.
l To activate the Motor servo again, input the “SV” command or the “MS” command.
l When the “MS” command is input, the Motor gets in the servo-on state. This also clears the
inputted operation command previously.
MS : Motor Stop
Format : MS
l When the “MS” command is input during the execution of an operation, the Motor abandons the
programs and stops. At this time, the Motor is in the servo-on state.
l The programs specified before the Motor stop are cleared. If the “MO” command is input to turn
off the Motor servo, inputting the MS command sets the Motor to servo-on again. This also clears
the programs being executed before the input of the “MO” command.