10-20
10.3.1. RS-232C Communication Command
l In the velocity control mode, the operation of the Motor can be executed through RS-232C
communication command.
l Setting the parameter AC (AC0) makes the DC command valid.
Then input
CD
ENT
(
data
)
to control the Motor under the proportional speed to the command data value.
l The relation between the command DC data and velocity is shown in Figure 10-12.
Figure 10-12
+1365 +4095
+4095
-4095
-4095 -1365
When the resolver resolution is
12 bit.
CCW maximum
velocity
CW maximum
velocity
When the resolver resolution is
10 bit or automatic switching.
CCW maximum
velocity
CW maximum
velocity
Caution : When the polarity of the position scale is reversed by setting DI parameter,
the polarity of DC command is also reversed.
Table 10-12 [s
-1
]
Maximum velocity
Motor series
Resolver resolution: 12 bit
Resolver resolution: 10 bit
or automatic switching
YS, JS1, JS2, RS 1 3
SS 1.25 3.75
AS, BS, JS0 1.5 4.5