14-9
14.2.4. Alarms Related to Control
14.2.4.1. Memory Error
[Output] DRDY: Open
[TA] E0 > Memory Error
[LED] E0
[Motion Condition] Servo-OFF
Table 14-10: Cause and Remedy: Memory error
Cause Remedy
(1) Parameters stored in the memory have been
rewritten by noise or other cause.
Initialize the memory then reenter the parameters.
(Refer to “12. Command and Parameter.”)
(2) Faulty PCB.
(When the memory is not functioning after
initialized.)
Replace Driver Unit.
Standard ESA Driver--------------------[Appendix 4]
Command “SI” (RS-232C communication) initializes the memory. After initializing, some
parameters are reset to shipping set. Resetting parameters to actual use condition are
necessary.
14.2.4.2. EEPROM Error
[Output] DRDY: Open
[TA] E2 > EEPROM Error
[LED] E2
[Motor Condition] Servo-OFF
Table 14-11: Cause and Remedy: EEPROM error
Cause Remedy
(1) Faulty EEPROM of control circuit. Turn the power on again.
Replace Driver Unit.
Standard ESA Driver--------------------[Appendix 4]
14.2.4.3. System Error
[Output] DRDY: Open
[TA] E7>System Error
[LED] E7
[Motor Condition] Servo-OFF
Table 14-12: Cause and Remedy: System Error
Cause Remedy
(1) Faulty ROM on PCB.
(2) Faulty EEPROM on PVB.
Replace Driver Unit.
Standard ESA Driver--------------------[Appendix 4]