— 4-25 —
2  AC100V/110V ±10 %
Table 4-7 : Power supply capacity
Driver Unit Reference No.
Main power Max.
(exclude surge current)
Control power Max.
(exclude surge current)
M-ESA-Y2005V25 0.3 kVA
M-ESA-Y2020V25 0.7 kVA
M-ESA-Y3008V25 0.3 kVA
M-ESA-Y3040V25 0.9 kVA
M-ESA-Y4080V25 1.0 kVA
M-ESA-Y5120V25 1.0 kVA
M-ESA-J0002V25 0.4 kVA
M-ESA-J1003V25 0.4 kVA
M-ESA-J2006V25 0.7 kVA
M-ESA-J2014V25 0.7 kVA
50 VA
* For the power supply capacity of RS and SS series motors, refer to their specification
document.
Table 4-8 : Surge and leakage current
Control power Main power
Surge current 7A 80A
(40
Hz
 ~ 1
kHz
) 3 mA rms
Leakage current
( ~ 1
MHz
) 20 mA rms
u Environmental specifications
Table 4-9
Vibration resistance 0.5G (Conform to JIS-C0911.)
Line noise resistance 1500V 1µS (by noise simulator)
Mass 3kg
In operation Temperature: 0 ~ 50°C Humidity: 20 ~ 90 % ( no condensation)
Environmental
condition
In storage
Temperature: - 20 ~ 70°C Use indoors, free from dust, condensation
and corrosive gases.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com