5. Troubleshooting
l When the brake does not perform as intended, check followings.
u Brake is slipping.
1) Is the friction plate soiled with oil?
2) Is temperature of the brake too high? (over 100 °C)
3) Is excessive load applied to the machine?
u Sluggish operation of the brake
1) Is sufficient voltage being supplied?
2) Is the friction plate worn out ? (too much gap)
3) Is brake temperature too high? (over 100 °C)
u The brake does not operate entirely.
1) Breakage of coil and/or lead wire
2) Electrical circuit failure
3) Too much gap of the friction plate because of wear?
4) Is sufficient voltage being supplied?