5 Basic Settings
5 - 4
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
No.
Display condition
Parameters displayed when condition is met
7
To display parameters
when 2nd Control Method
is set to V/f control (con-
stant torque or reduced
torque)
C001 to C007 = 08 and A244 =
00 or 01
A241 to A243, A246, A247
8
To display parameters
when DC injection braking
is active
A051 = 00 or 01, or C001 to
C007 = 07
A052 to A059
9
To display parameters
when PID function is
enabled
A071 = 01 or 02
d004, A072 to A079, A156, A157, C044, C052, C053
10
To display parameters
when the co-inverter com-
munication is enabled
C096 = 01 or 02
C098 to C100, P140 to P155
11
To display parameters
when curve accelera-
tion/deceleration function is
enabled
A097, A098 = 01 to 04
A131, A132, A150 to A153
12
To display parameters
when deceleration stop on
power interruption function
is enabled
b050 = 01 to 03
b051 to b054
13
To display parameters
when brake control func-
tion is enabled
b120 = 01
b121 to b127
14
To display parameters
when overvoltage suppres-
sion function during decel-
eration is enabled
b130 = 01 or 02
b131 to b134
15
To display parameters
when simple position con-
trol is enabled
P003 = 01
d008, P004, P011, P012, P014 to P017, P026, P027,
P060 to P073, P075, P077, P080 to P083, H050, H051
User Setting (b037 = 02)
Data Comparison Display (b037 = 03)
Monitor Display Only (b037 = 05)

Table of Contents