Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1) 
 
 
 
 
 
 
 
7-6-12  Jog Dial Sensitivity   
 
Change the Jog Sensitivity Setting (C117) and Jog Carry Sensitivity Setting (C118) parameter values to 
adjust how much the value changes when the Jog dial is rotated. 
 
1 to 24 
Set the Jog dial count required 
to increase or decrease the 
value by 1. One rotation of the 
Jog dial corresponds to 24 
counts. 
 
 
 
 
Jog Carry Sensitivity Setting 
1 to 100 
When you operate the Jog dial 
continuously in the same 
direction during data setting, the 
digit that you can operate is 
shifted. Set the value required to 
shift the digit as the amount of 
increase or decrease of the 
display value per second. 
7-6  Digital Operator and Operation Functions 
7-6-12  Jog Dial Sensitivity