10 Troubleshooting
10 - 11
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Warning
display
Warning display conditions
1st Frequency Upper Limit (A061)

1st Maximum Frequency (A004)
1st Frequency Lower Limit (A062)

1st Maximum Frequency (A004)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)

1st Maximum Frequency (A004)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)

1st Frequency Upper Limit (A061)
1st Frequency Lower Limit (A062)

Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
Starting Frequency (b082)

1st Frequency Upper Limit (A061)
Starting Frequency (b082)

1st Frequency Lower Limit (A062)
Starting Frequency (b082)

Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
Starting Frequency (b082)

Jogging Frequency (A038)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
=
Jump Frequency
*1
(A063/A065/A067 ± A064/A066/A068)
Multi-step Speed Reference 1 to 15
(A021 to A035)
=
Free V/f Frequency 7 (b112)

1st Frequency Upper Limit (A061)
Free V/f Frequency 7 (b112)

1st Frequency Lower Limit (A062)
Free V/f Frequency 7 (b112)

Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
2nd Frequency Upper Limit (A261)

2nd Maximum Frequency (A204)
2nd Frequency Lower Limit (A262)

2nd Maximum Frequency (A204)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)

2nd Maximum Frequency (A204)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)

2nd Frequency Upper Limit (A261)
2nd Frequency Lower Limit (A262)

Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
Starting Frequency (b082)

2nd Frequency Upper Limit (A261)
Starting Frequency (b082)

2nd Frequency Lower Limit (A262)
Starting Frequency (b082)

Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
=
Jump Frequency
*1
(A063/A065/A067 ± A064/A066/A068)
Free V/f Frequency 7 (b112)

2nd Frequency Upper Limit (A261)
Free V/f Frequency 7 (b112)

2nd Frequency Lower Limit (A262)
Free V/f Frequency 7 (b112)

Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
10
10-1 Alarm Display and Reme-
dies
10-1-4 Warning Display