EasyManuals Logo

Omron 3G3MX2-A2002-EV2 User Manual

Omron 3G3MX2-A2002-EV2
612 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #372 background imageLoading...
Page #372 background image
7 Other Functions
7 - 36
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter No.
Function name
Data
Default
data
Unit
b036
Reduced Voltage
Startup Selection
0: Reduced voltage startup disabled
1 (Reduced voltage startup time: short) to
255 (Reduced voltage startup time: long)
2
−
Related functions
b082
Parameter
No.
Function name
Data
Default
data
Unit
A063/A065/
A067
Jump Frequency 1/2/3
0.00 to 590.00
Set the center of the jump frequency.
*1
0.00
Hz
A064/A066/
A068
Jump Frequency Width
1/2/3
0.00 to 10.00 (100.00)
*2
Set 1/2 of the jump frequency width.
0.50
Hz

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3MX2-A2002-EV2 and is the answer not in the manual?

Omron 3G3MX2-A2002-EV2 Specifications

General IconGeneral
BrandOmron
Model3G3MX2-A2002-EV2
CategoryInverter
LanguageEnglish

Related product manuals