7 Other Functions
7 - 90
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Data
Default
data
Unit
C038
Low Current Signal Output Selection
00: Enabled during accelera-
tion/deceleration and
constant speed
01: Enabled during constant
speed
*1
01
C039
Low Current Detection Level
0.00 to 2.00 Rated current
Set the output level of the low
current signal.
Rated
current
A
C021, C022
Multi-function Output 11/12 Selection
43: LOC (Low current signal)
C026
Multi-function Relay Output (AL1, AL2)
Function Selection
Alarm code
Description
E08.
EEPROM error
E11.
CPU error
E14.
Ground protection
E30.
Driver error
Parameter
No.
Function name
Data
Default
data
Unit
C021, C022
Multi-function Output 11/12 Selection
53: MJA (Fatal fault signal)
C026
Multi-function Relay Output (AL1, AL2)
Function Selection