5 Basic Settings
5 - 23
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Data
Default data
Unit
A001/A201
1st/2nd Frequency
Reference Selec-
tion
*1
00:
Digital Operator (Volume)
*2
01: Control circuit terminal block
(Analog input)
02: Digital Operator (F001)
03: Modbus communication
04: Option
06: Pulse train frequency
07: DriveProgramming
10:
Operation function output
*3
02
−
F001
Output Frequency
Setting/Monitor
0.00, Starting Frequency to 1st/2nd Max-
imum Frequency
When the PID function is enabled: 0.00
to 9999.00
*4
6.00
Hz
%
Related functions
A005, A141 to A143, A145, A146