Omron 3G3MX2-A2002-EV2 - Adjustments for V;F Control with Speed Feedback

Omron 3G3MX2-A2002-EV2
612 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Vector Control and Applied Functions
6 - 24
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Speed feedback
Frequency reference
Set frequency
Parameter No.
Function name
Data
Default
data
Unit
H050
V/f Control With Speed Feedback
Slip Compensation Proportional
Gain
0.00 to 10.00
0.20
Time
H051
V/f Control with Speed Feedback
Slip Compensation Integral Time
0. to 1000.
2.
s
Proportional gain
(H050)
Integral gain
(H051)