6 Vector Control and Applied Functions
6 - 16
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Data
Default
data
Unit
P033
Torque Reference Input
Selection
00: Terminal O (10 V = 200%)
01: Terminal OI (20 mA = 200%)
03: Digital Operator (P034 setting)
06: Option (No applicable Option)
00
P034
Torque Reference Setting
0. to 200.
(Torque reference when P033 = 03)
0.
%
P039
Speed Limit Value in Torque
Control (Forward)
0.00 to 120.00
0.00
Hz
P040
Speed Limit Value in Torque
Control (Reverse)
0.00 to 120.00
0.00
Hz
P041
Speed/Torque Switching
Time
0. to 1000.
0.
ms
C001 to
C007
Multi-function Input 1 to
7 Selection
52: ATR (Torque reference input permis-
sion)

Table of Contents