6 Vector Control and Applied Functions
6 - 20
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Input signal type
Maximum Fre-
quency
Terminal EA
(5 to 24 VDC, 32 kHz max.)
Terminal 7/EB
(24 VDC, 32 kHz max.)
Single-phase pulse train (P004
= 00)
Terminal EA: 32 kHz
Terminal 7
(Terminal EB):
32 kHz
Single-phase pulse train
Phase A and B 90°phase differ-
ence pulse train (P004 = 01)
Phase-A pulse train
Phase-B pulse train
Single-phase pulse train + direc-
tion (P004 = 03)
Single-phase pulse train
Direction signal
*1
Encoder Input
Wiring for Phase A and B 90°Phase Difference Pulse Train (P004 = 01)