EasyManua.ls Logo

Omron 3G3MX2-A2002-EV2 - Page 307

Omron 3G3MX2-A2002-EV2
612 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Vector Control and Applied Functions
6 - 39
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Data
Default data
Unit
C102
Reset Selection
03: Trip reset only
02
P072
Position Limit Setting
(Forward Side)
0 to 268435455
(Displays upper 5 digits)
(1 multiplication)
*1
268435455
pulse
P073
Position Limit Setting
(Reverse Side)
268435455 to 0
(Displays upper 5 digits including ”)
(1 multiplication)
*1
268435455
pulse
P026
Overspeed Error Detec-
tion Level
0.0 to 150.0
*2
115.0
%
P027
Speed Deviation Exces-
sive Level
0.00 to 120.00
10.00
Hz
P015
Creep Speed Setting
Starting Frequency to 10.00 (100.00)
*3
5.00
Hz
P077
Encoder Disconnection
Detection Time
0.0:
Disconnection detection disabled
0.1 to 10.0
1.0
s
C021, C022
Multi-function Output 11,
12 Selection
22: DSE (Excessive speed deviation)
C026
Multi-function Relay Out-
put (AL1, AL2) Function
Selection
05
Parameter
No.
Function name
Data
Default
data
Unit
d008
Real Frequency Monitor
*1
590.00 to 590.00
Hz
d029
Position Command Monitor
*2
268435455 to 268435455 (1 multiplication)
(Displays upper 4 digits including ”)
pulse
d030
Current Position Monitor
*3
268435455 to 268435455 (1 multiplication)
(Displays upper 4 digits including ”)
pulse
6
6-7 Simple Position Control
6-7-3 Simple Position Control Operation and Settings
Monitor Functions under Simple Position Control