6 Vector Control and Applied Functions
6 - 46
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Data
Default
data
Unit
P060
Multi-step Position
Command 0
Position Limit Setting (Reverse Side) (P073) to
Position Limit Setting (Forward Side) (P072)
*1
(Displays upper 5 digits excluding “-”)
( 1 multiplication)
0
pulse
P061
Multi-step Position
Command 1
0
P062
Multi-step Position
Command 2
0
P063
Multi-step Position
Command 3
0
P064
Multi-step Position
Command 4
0
P065
Multi-step Position
Command 5
0
P066
Multi-step Position
Command 6
0
P067
Multi-step Position
Command 7
0
C001 to C007
Multi-function Input
Selection
66: CP1 (Position command selection 1)
67: CP2 (Position command selection 2)
68: CP3 (Position command selection 3)
C169
Multi-step Speed/Posi-
tion Determination
Time
0 to 200 ( 10 ms)
Time until terminal input is recognized.
0
ms
Position command
CP3
CP2
CP1
Multi-step position 0
0
0
0
Multi-step position 1
0
0
1
Multi-step position 2
0
1
0
Multi-step position 3
0
1
1
Position command
CP3
CP2
CP1
Multi-step position 4
1
0
0
Multi-step position 5
1
0
1
Multi-step position 6
1
1
0
Multi-step position 7
1
1
1

Table of Contents