7 Other Functions
7 - 23
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Setting item
Function name
Data
Default
data
Unit
00: Terminal O
P033
Torque Reference
Input Selection
10 V = 200%
01: Terminal OI
00
Torque control
20 mA = 200%
C001 to
C007
Multi-function Input 1
to 7 Selection
52: ATR
(Torque reference input
permission)
Parameter
No.
Function
name
Data
Default
data
Unit
A005
O/OI
Selection
00: Switches between current and voltage based on ter-
minal AT (Analog input switching) status.
Terminal AT (Analog input switching) ON: Current
Terminal AT (Analog input switching) OFF:
Voltage
02: Enabled only when 3G3AX-OP01 is used.
Switches between voltage and VR based on terminal
AT (Analog input switching) status.
Terminal AT (Analog input switching) ON: VR
Terminal AT (Analog input switching) OFF: Voltage
03: Enabled only when 3G3AX-OP01 is used.
Switches between current and VR based on terminal
AT (Analog input switching) status.
Terminal AT (Analog input switching) ON: VR
Terminal AT (Analog input switching) OFF:
Current
00
C001 to
C007
Multi-function
Input 1 to 7
Selection
16: AT (Analog input switching)
7
7-3 Analog I/O Settings
7-3-1 Analog Input (O, FI)