7 Other Functions
7 - 72
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
b050
b052
Operation
02 (without recovery)
b052 > Main circuit DC voltage at incoming
voltage recovery
Deceleration stop (DC
(Example 1)
voltage constant control)
b052 < Main circuit DC voltage at incoming
voltage recovery
Deceleration stop (Normal
(Example 2)
operation)
03 (with recovery)
b052 > Main circuit DC voltage at incoming
voltage recovery
Deceleration stop (DC
(Example 1)
voltage constant control)
b052 < Main circuit DC voltage at incoming
voltage recovery
Operation (Normal operation) (Example 2)
Deceleration Stop on Power Interruption Function: DC Voltage Kept
Constant (b050 = 02: Without Recovery/b050 = 03: With Recovery)
7
7-7 Restart Functions
7-7-4 Deceleration Stop on Power Interruption Function
b054