8 - 59
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1288 to
12A4
hex
Reserved
12A5
hex
12A4 hex
Acceleration Curve
Parameter
A131
R/W
1 (Small curve) to 10
(Large curve)
P. 5-33
12A6
hex
12A5 hex
Deceleration Curve
Parameter
A132
R/W
1 (Small curve) to 10
(Large curve)
12A7
to
12AE
hex
Reserved
12AF
hex
12AE hex
Calculation
Frequency
Selection 1
A141
R/W
00:
Digital Operator
(A020/A220)
01:
Volume
*1
02: Voltage (O) input
03: Current (OI) input
04:
Modbus communication
05: Option
07:
Pulse train frequency
P. 7-39
12B0
hex
12AF hex
Calculation
Frequency
Selection 2
A142
R/W
00:
Digital Operator
(A020/A220)
01:
Volume
*1
02: Voltage (O) input
03: Current (OI) input
04:
Modbus communication
05: Option
07:
Pulse train frequency
12B1
hex
12B0 hex
Calculation Function
Operator Selection
A143
R/W
00:
Addition (A141
+
A142)
01:
Subtraction (A141
A142)
02:
Multiplication
(A141 A142)
12B2
hex
Reserved
12B3
hex
12B2 hex
Frequency Addition
Amount Setting
A145
(HIGH)
R/W
0 to 59000
0.01
[Hz]
*2
P. 7-39
12B4
hex
12B3 hex
A145
(LOW)
R/W
12B5
hex
12B4 hex
Frequency Addition
Sign Selection
A146
R/W
00:
Frequency
reference
+
A145
01:
Frequency
reference
A145
12B6 to
12B8
hex
Reserved
12B9
hex
12B8 hex
EL-S Shape
Acceleration Curve
Ratio 1
A150
R/W
0 to 50
1 [%]
P. 5-33
12BA
hex
12B9 hex
EL-S Shape
Acceleration Curve
Ratio 2
A151
R/W
0 to 50
1 [%]
12BB
hex
12BA hex
EL-S Shape
Deceleration Curve
Ratio 1
A152
R/W
0 to 50
1 [%]
12BC
hex
12BB hex
EL-S Shape
Deceleration Curve
Ratio 2
A153
R/W
0 to 50
1 [%]