8 Communications Functions
8 - 62
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1316
hex
1315 hex
1st Overload Limit
Selection
b021
R/W
00: Disabled
01: Enabled during
acceleration and
constant speed
02: Enabled during
constant speed
03: Enabled during
acceleration and
constant speed
(Accelerated
during regenera-
tion)
P. 7-78
1317
hex
1316 hex
1st Overload Limit
Level
b022
R/W
200 to 2000 (1500)
0.1 [%]
1318
hex
1317 hex
1st Overload Limit
Parameter
b023
R/W
1 to 30000
0.1 [s]
1319
hex
1318 hex
1st Overload Limit
Selection 2
b024
R/W
00: Disabled
01: Enabled during
acceleration and
constant speed
02: Enabled during
constant speed
03: Enabled during
acceleration and
constant speed
(Accelerated
during regenera-
tion)
131A
hex
1319 hex
1st Overload Limit
Level 2
b025
R/W
200 to 2000 (1500)
0.1 [%]
131B
hex
131A hex
1st Overload Limit
Parameter 2
b026
R/W
1 to 30000
0.1 [s]
131C
hex
131B hex
Overcurrent
Suppression
Selection
b027
R/W
00: Disabled
01: Enabled
02: Enabled (at reduced
voltage startup)
P. 7-81
131D
hex
131C hex
Frequency Pull-in
Restart Level
b028
R/W
200 to 2000 (1500)
0.1 [%]
P. 5-44
P. 7-62
131E
hex
131D hex
Frequency Pull-in
Restart Parameter
b029
R/W
1 to 30000
0.1 [s]
131F
hex
131E hex
Starting Frequency
Selection at Fre-
quency Pull-in
Restart
b030
R/W
00: Frequency at
interruption
01: Maximum fre-
quency
02: Set frequency
(Frequency refer-
ence)