00: FW (Forward)
01:
RV
(Reverse)
02: CF1 (Multi-step speed setting binary 1)
03: CF2 (Multi-step speed setting binary 2)
04: CF3 (Multi-step speed setting binary 3)
05: CF4 (Multi-step speed setting binary 4)
06: JG (Jogging)
07: DB (External DC injection braking)
08: SET (2nd control)
09: 2CH (2-step acceleration/deceleration)
11: FRS (Free-run stop)
12:
EXT
(External
trip)
13:
USP (Power recovery restart prevention function)
14: CS (Commercial switch)
15:
SFT
(Soft
lock)
16: AT (Analog
input
switching)
18: RS (reset)
19: TH (PTC thermistor thermal protection)
<C005
only>
20: STA (3-wire start)
21:
STP
(3-wire
stop)
22: F/R (3-wire forward/reverse)
23: PID (PID disabled)
24:
PIDC
(PID
integral
reset)
27: UP (Remote operation accelerated)
28: DWN (Remote operation decelerated)
29: UDC (Remote operation data clear)
31: OPE (Forced operator function)
32: SF1 (Multi-step speed setting bit 1)
33: SF2 (Multi-step speed setting bit 2)
34: SF3 (Multi-step speed setting bit 3)
35: SF4 (Multi-step speed setting bit 4)
36: SF5 (Multi-step speed setting bit 5)
37: SF6 (Multi-step speed setting bit 6)
38: SF7 (Multi-step speed setting bit 7)
39: OLR (Overload limit switching)
40:
TL
(Torque
limit
enabled)
41:
TRQ1
(Torque
limit
switching
1)
42: TRQ2 (Torque
limit
switching 2)
44: BOK (Brake confirmation)
46: LAC (LAD cancel)
47:
PCLR
(Current
position
clear)
50: ADD (Set frequency A145 addition)
51: F-TM (Forced terminal block)
52: ATR (Torque reference
input
permission)
53: KHC (Integrated power clear)
56:
MI1
(General-purpose
input
1)
57:
MI2
(General-purpose
input
2)
58:
MI3
(General-purpose
input
3)
59:
MI4
(General-purpose
input
4)
60:
MI5
(General-purpose
input
5)
61:
MI6
(General-purpose
input
6)
62: MI7 (General-purpose input 7)
65: AHD (Analog command held)
66:
CP1
(Position
command
selection
1)
67:
CP2
(Position
command
selection
2)
68: CP3 (Position command selection 3)
69: ORL (Origin search limit signal)
70: ORG (Origin search startup signal)
73: SPD (Speed/Position switching)
81: 485 (Start co-inverter communication)
82: PRG (DriveProgramming start)
83:
HLD
(Retain
output
frequency)
84: ROK (Permission of RUN command)
85: EB (Rotation direction detection)
86: DISP (Display fixed)
91: PSET (Preset position)
255: no (No allocation)