C-mode Command List Section 4-1
C-mode Command Force Conditions
Header
code
Name Single-
frame
com-
mand
Multiple-
frame
command
Single-
frame
response
Multiple-
frame
response
RUN MON PRG UM
write
protect
UM
read
protect
RR CIO AREA READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
RL LR AREA READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
RH HR AREA READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
RC PV READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
RG TC STATUS READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
RD DM AREA READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
RJ AR AREA READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
RE EM AREA READ Valid Not valid Valid Valid Valid Valid Valid Valid Valid
WR CIO AREA WRITE Valid Valid Valid Not valid Not
valid
Valid Valid Valid Valid
WL LR AREA WRITE Valid Valid Valid Not valid Not
valid
Valid Valid Valid Valid
WH HR AREA WRITE Valid Valid Valid Not valid Not
valid
Valid Valid Valid Valid
WC PV WRITE Valid Valid Valid Not valid Not
valid
Valid Valid Valid Valid
WD DM AREA WRITE Valid Valid Valid Not valid Not
valid
Valid Valid Valid Valid
WJ AR AREA WRITE Valid Valid Valid Not valid Not
valid
Valid Valid Valid Valid
WE EM AREA WRITE Valid Valid Valid Not valid Not
valid
Valid Valid Valid Valid
R# SV READ 1 Valid Not valid Valid Not valid Valid Valid Valid Valid Not
valid
R$ SV READ 2 Valid Not valid Valid Not valid Valid Valid Valid Valid Not
valid
R% SV READ 3 Valid Not valid Valid Not valid Valid Valid Valid Valid Not
valid
W# SV CHANGE 1 Valid Not valid Valid Not valid Not
valid
Valid Valid Not
valid
Not
valid
W$ SV CHANGE 2 Valid Not valid Valid Not valid Not
valid
Valid Valid Not
valid
Not
valid
W% SV CHANGE 3 Valid Not valid Valid Not valid Not
valid
Valid Valid Not
valid
Not
valid
MS STATUS READ Valid Not valid Valid Not valid Valid Valid Valid Valid Valid
SC STATUS CHANGE Valid Not valid Valid Not valid Valid Valid Valid Valid Valid
MF ERROR READ Valid Not valid Valid Not valid Valid Valid Valid Valid Valid
KS FORCED SET Valid Not valid Valid Not valid Not
valid
Valid Valid Valid Valid
KR FORCED RESET Valid Not valid Valid Not valid Not
valid
Valid Valid Valid Valid
FK MULTIPLE
FORCED
SET/RESET
Valid Not valid Valid Not valid Not
valid
Valid Valid Valid Valid
KC FORCED SET/
RESET CANCEL
Valid Not valid Valid Not valid Not
valid
Valid Valid Valid Valid
MM PLC MODEL
READ
Valid Not valid Valid Not valid Valid Valid Valid Valid Valid
TS TEST Valid Not valid Valid Not valid Valid Valid Valid Valid Valid
RP PROGRAM READ Valid Not valid Valid Valid Valid Valid Valid Valid Not
valid