FINS Commands Section 5-3
If the data is too large and exceeds the permissible length of the response for-
mat, the part in excess will not be read and a normal response will be
returned.
5-3-29 ERROR LOG CLEAR: 21 03
Clears all error log pointers to 0.
Execution Conditions
Command Format
Response Format
End code (response)
Refer to 5-1-3 End Codes for information on end codes.
Comments This command clears the number of error log records that are stored. It does
not clear data from the error log area.
5-3-30 FINS WRITE ACCESS LOG READ: 21 40
The CPU Unit automatically keeps a log of any access for FINS write com-
mands regardless of the setting. This command reads this log, which tells the
nodes and time when there was access.
Execution Conditions
Command Format
Access right at
other device
UM read
protection
DIP switch UM write
protection
Network write
protection
No OK OK No
RUN mode MONITOR mode PROGRAM mode
OK OK OK
Command
format
0321
Command
format
03
21
End code
Access right at
other device
UM read
protection
DIP switch UM
write protection
Network write
protection
OK OK OK OK
RUN mode MONITOR mode PROGRAM mode
OK OK OK
Command
code
40
21
Beginning
record No.
No. of
records

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ - REFERENCE MANUAL 07-2009 and is the answer not in the manual?

Omron CJ - REFERENCE MANUAL 07-2009 Specifications

General IconGeneral
BrandOmron
ModelCJ - REFERENCE MANUAL 07-2009
CategoryComputer Hardware
LanguageEnglish

Related product manuals