222
FINS Commands Section 5-3
Disk number (command)
The classification of the file memory where the file to be transferred or com-
pared is registered is specified as follows:
8000 (hex): Memory card
8001 (hex): EM file memory
File name (command)
Specify the file to be transferred or compared. For details on the configuration,
refer to page 168.
Directory length
Indicates the length of the absolute directory path. The maximum number of
characters is 65. To specify the root directory as the absolute directory path,
specify 0000 (hex) as the directory length.
Absolute directory path
Indicates the absolute path from the root directory. It begins with \ (5C hex),
and the drive name and colon (:) are not required. “\” is used to delimit the
lower directory. It is not required at the end of the final absolute path. No set-
ting is required to specify the root directory itself.
Comments MEMORY AREA–FILE TRANSFER (command code 220A) can be executed
regardless of the CPU Unit mode. It is the user’s responsibility to program
steps to prohibit this command from being executed when the CPU Unit is in
RUN mode if such protection is necessary. Execute CPU UNIT STATUS
READ (command code 0601) to read the CPU Unit’s mode. (Refer to 5-3-17
CPU UNIT STATUS READ: 06 01.)
If data is written to the Timer/Counter PV Area, the Completion Flags will not
be turned OFF.
The CPU Unit clock data upon completion of MEMORY AREA–FILE TRANS-
FER (command code 220A) will be recorded as the date of the file that has
been transferred.
Files cannot be overwritten when transferring data from a memory area to file
memory.
End code (response)
Refer to 5-1-3 End Codes for information on end codes.
5-3-40 PARAMETER AREA–FILE TRANSFER: 22 0B
Compares or transfers data between the parameter area and the file memory.
Execution Conditions
Note Data cannot be transferred from file memory to the parameter area.
Command Format
Access right at
other device
UM read
protection
DIP switch UM write
protection
Network write
protection
No OK OK (See note.) No
RUN mode MONITOR mode PROGRAM mode
OK (See note.) OK (See note.)
OK
22 0B
File name
Parameter area specification File specification
Parameter
area code
Beginning
address
Disk No.Command
code
Parameter
code
No. of
items
12 bytes
Directory
length
Absolute directory
path

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ - REFERENCE MANUAL 07-2009 and is the answer not in the manual?

Omron CJ - REFERENCE MANUAL 07-2009 Specifications

General IconGeneral
BrandOmron
ModelCJ - REFERENCE MANUAL 07-2009
CategoryComputer Hardware
LanguageEnglish

Related product manuals