Precautions when Reusing Programs from Earlier Models Section 2-4
Note When using CVM1 or CV-series built-in ports or Host Link Units, the response
data format for the MS command (STATUS READ) is different from the format
for other Units. For details, refer to 4-3-23 STATUS READ – – MS.
NA W$ TIMER/
COUNTER SV
CHANGE 2
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s N o Ye s N o
NA W% TIMER/
COUNTER SV
CHANGE 3
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s N o N o Ye s N o
N A M S S TAT U S R E A D Ye s Ye s Ye s Ye s Ye s Ye s Ye s Yes Ye s Ye s Ye s Ye s Ye s Ye s
NA SC STATUS
CHANGE
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
N A M F E R R O R R E A D Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Yes Ye s Ye s Ye s
NA KS FORCED SET Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
NA KR FORCED
RESET
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA FK MULTIPLE
FORCED SET/
RESET
Yes Yes Yes No Yes No No No No Yes Yes No Yes No
NA FR MULTIPLE
FORCED SET/
RESET STA-
TUS READ
No Yes Yes No Yes No No No No No No No No No
NA KC FORCED SET/
RESET CAN-
CEL
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA MM PLC MODEL
READ
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
N A T S T E S T Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA RP PROGRAM
READ
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA WP PROGRAM
WRITE
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA MI I/O TABLE
CREATE
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s N o N o Ye s Ye s Ye s
NA QQMR/
QQIR
REGISTER/
READ I/O
MEMORY
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA XZ ABORT (com-
mand only)
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA ** INITIALIZE
(command
only)
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA IC Undefined
command
(response only)
Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s Ye s
NA EX TXD
RESPONSE
(response only)
NoYes NoNoNo NoNoNoNo NoNoNoNoNo
NA FA FINS MES-
SAGE
YesNo NoNoNo NoNoNoNo NoNoYesYesYes
NA OF FINS MES-
SAGE (slave-
initiated)
YesNo NoNoNo NoNoNoNo NoNoYesYesYes
Frame
data
size
Header
code
Name CS/CJ
Series
C Series CVM1 and
CV Series
C200HE
/HG/HX
C200HS C120 C200H
C200HS
C200HE/
HG/HX
C500 C1000H
C2000H
C500F C1000HF CQM1 SRM1
CPM1
CPM1A
--- --- --- --- --- --- --- --- None
or V1
V2 ---
CPU Unit or Serial
Communications Board or Unit
CPU Unit or
Communications Board
CPU Unit
C120 (3G2A6) Host Link Unit
C200H Host Link Unit
C500 (3G2A5) Host Link Unit
CPU Unit
CPU Unit
CPU Unit
CPU Unit
CV500 Host Link Unit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ - REFERENCE MANUAL 07-2009 and is the answer not in the manual?

Omron CJ - REFERENCE MANUAL 07-2009 Specifications

General IconGeneral
BrandOmron
ModelCJ - REFERENCE MANUAL 07-2009
CategoryComputer Hardware
LanguageEnglish

Related product manuals