EasyManua.ls Logo

Omron F3SG-SR Series - Conformity and Environmental Ratings

Omron F3SG-SR Series
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
F3SG-SR/PG
50
Electrical
Input voltage
TEST
Light emission stops when connected to 24 V DC
ON voltage: Vs-3 V to Vs (short circuit current: approx. 5.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 6.0 mA) *
Light emission stops when connected to 0 V
ON voltage: 0 to 3 V (short circuit current: approx. 6.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 5.0 mA) *
OPERATING
RANGE SELECT
INPUT
Long: 12 V to Vs (short circuit current: approx. 4.2 mA) * or open
Short: 0 to 3 V (short circuit current: approx. 4.2 mA)
RESET/EDM
PNP ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *
NPN ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *
MUTE A/B,
RE-RESET, PSDI
PNP ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *
NPN ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *
* The Vs indicates a supply voltage value in your environment.
Overvoltage category (IEC 60664-1) II
Indicators Refer to page 63
Protective circuit Output short-circuit protection
Insulation resistance 20 MΩ or higher (500 VDC megger)
Dielectric strength 1,000 VAC, 50/60 Hz (1 min)
Functional
Mutual interference prevention
Optical synchronization by Scan Code: in up to 2 sets
Wired synchronization: in up to 3 sets
Cascade connection
Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Test function
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-related functions
Interlock
External Device Monitoring (EDM)
Pre-Reset
PSDI
Fixed Blanking/Floating Blanking
Reduced Resolution
Muting/Override
Mutual Interference Prevention
PNP/NPN Selection
Response Time Adjustment
Environmental
Ambient
temperature
Operating -30 to 55 °C (non-icing)
Storage -30 to 70 °C
Ambient
humidity
Operating 35% to 85% (non-condensing)
Storage 35% to 95%
Ambient illuminance
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of protection (IEC 60529) IEC 60529: IP65 and IP67, JIS C 0920 Annex 1: IP67G
Vibration resistance (IEC 61496-1) 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock resistance (IEC 61496-1) 100 m/s
2
, 1000 shocks for all 3 axes
Pollution degree (IEC 60664-1) 3
Connections
Root cable
Type of
connection
To sensors: dedicated connector, To external: M12 connector type (5-pin emitter and 8-pin receiver) or
open-ended type
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
* The F3SG-SR meets the degree of protection when the root cable is correctly connected with the F3SG-
SR. The degree of protection is not satisfied with the part where cable wires are uncovered.
Number of wires Emitter: 5, Receiver: 8
Cable length Refer to page 38
Cable diameter 6 mm
Minimum bending
radius
R5 mm
Cascading cable
Type of
connection
To sensors: dedicated connector, To cascading sensors: M12 connector type (5-pin emitter and 8-pin
receiver) or dedicated connector
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
* The F3SG-SR meets the degree of protection when the cascading cable is correctly connected with the
F3SG-SR and the root cable.
Number of wires Emitter: 5, Receiver: 8
Cable length Refer to page 40
Cable diameter 6 mm
Minimum bending
radius
R5 mm
Model
F3SG-@SRA@@@@-14
F3SG-@SRB@@@@-14
F3SG-@SRA@@@@-25
F3SG-@SRB@@@@-25
F3SG-@SRA@@@@-45
F3SG-@SRB@@@@-45
F3SG-@SRA@@@@-85
F3SG-@SRB@@@@-85

Table of Contents