Functions and Operations
Section 5 Functions and Operations
5-6
■
Monitoring and Changing Set Values
Values set to each parameter are called "set values".
Set values can be numerals or characters.
When the SV display is lit, it is called the "monitor status". When the
SV display is flashing, it is called the "change status".
Use the following procedure to change set values.
Procedure
• At this stage, set values are displayed but cannot be changed.
• The place that can be changed starts to flash.
• The changed set value is stored in the internal memory.
• If no key is pressed at step C for 5 s*, the set value is registered
and the display automatically returns to monitor status.
* If the display is on RUN level or adjustment level, the time before the
return to monitor status differs depending on the setting for
"Automatic display return time". If the "automatic display return time"
setting is less than 5 s, for example, 3 s, then if there are no key
operations in change status for 3 s, the changed set value is
registered and the display automatically returns to the display when
the power was turned ON.
A The parameter to be changed is displayed.
B Press the S[SHIFT] Key once to enable the setting to be
changed.
C Use the S[SHIFT] and U[UP] Keys to change the setting.
D Press the M[MODE] Key to switch to the next parameter.
1-5
int-a
M
M
S
Change status
Monitor status
To next parameter
If no key is pressed for 5 seconds, the
set value is registered and the display
returns to monitor status.
Use the S [SHIFT]
and U [UP] Keys to
set the set value.
M
1-5
int-a