EasyManuals Logo

Omron M1 Series User Manual

Omron M1 Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #304 background imageLoading...
Page #304 background image
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
A19
2nd Online tuning 
Function Selection
0: Disable
1: Enable
0
Availa-
ble
-
page
6-71
A20
2nd Motor Armature
Resistance
0.00 to 500.0 A
10.55 - A
page
6-6
A21
2nd Motor Motor Con-
stant %R1
0.00 to 50.00 %
3.17
Availa-
ble
%
page
6-65
A22
2nd Motor Motor Con-
stant %X
0.00 to 50.00 %
11.47
Availa-
ble
%
page
6-65
A23
2nd Slip Compensa-
tion Gain for Driving
0.0 to 200.0 %
100.0
Availa-
ble
%
page
5-16
A24
2nd Slip Compensa-
tion Response Time
0.01 to 10.00 s
0.12
Availa-
ble
s
page
5-16
A25
2nd Slip Compensa-
tion Gain for Braking
0.0 to 200.0 %
100.0
Availa-
ble
%
page
5-16
A26
2nd Rated Slip Fre-
quency
0.00 to 15.00 Hz
1 - Hz
page
5-16
A27 2nd Iron Loss Factor 1
0.00 to 20.00 %
2.86
Availa-
ble
%
page
6-6
A30
2nd Magnetic Satura-
tion Factor 1
0.0 to 300.0 %
92
Availa-
ble
%
page
6-65
A31
2nd Magnetic Satura-
tion Factor 2
0.0 to 300.0 %
84.2
Availa-
ble
%
page
6-65
A32
2nd Magnetic Satura-
tion Factor 3
0.0 to 300.0 %
70.5
Availa-
ble
%
page
6-65
4 Parameter List
4-138
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C